Power Control 480V, 50-60 Hz, 3 Phase, 3 Wire, Delta, Ungrounded - Standard

$4,495.00
PC101

Spikes, surges, zaps and transients are all terms used to describe temporary over-voltage power line disturbances. These disturbances can be addressed with transient voltage surge suppressors (TVSS)

If you have experienced any of these symptoms in your business:

It's time to get a Power Control Industrial Strength surge Suppressor!

Power Control 480V, 50-60 Hz, 3 Phase, 3 Wire, Delta, Ungrounded - Heavy Duty

TRANSIENT VOLTAGE SURGE SUPPRESSORS
FULL TEN YEAR WARRANTY


For ten (10) years from the date of purchase, POWER CONTROL INTERNATIONAL will repair or replace the Transient Voltage Surge Suppressor(s) (TVSS) free of charge if defective in material or workmanship, or if failure is due to a lightning strike.

To obtain warranty service, the TVSS(s) must be returned to POWER CONTROL or its local representative. Remedy under this warranty is limited to repair or replacement of the TVSS(s) as provided above. POWER CONTROL will not be liable loss or damage due directly or indirectly to occurrences which the TVSS(s) is not designed to prevent.

POWER CONTROL will nullify this warranty if the unit is not installed by a qualified electrician, distributor or dealer of our TVSS.

Some states do not allow exclusion or limitation of incidental or consequently damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.

This warranty is not transferable by the original purchaser.

INSTALLATION INSTRUCTIONS

The PCI-TVSS may be installed to the lugs of the main, the lugs of any switch, or any breaker on a circuit-breaker panel (CBP).

Mount the unit as close as possible to the point of attachment. The wires coming out of the unit are three feet long, but do not use all three feet unless you have to--the closer the better.

The black wires are attached to the A, B and C Phase of the lugs, or on a CBP to any three-phase breaker on the panel. Just loosen the set screw, insert the wire and tighten the set screw.

On Center-Tap Grounded units, there will be only two black wires The B-phase is neutral.

On Hi-Leg service, the Hi-Leg wire will be red.

The green ground wire should be attached to the cabinet neutral or the cabinet ground.

CAUTION: Before installing. be sure to check all three phases to ground to be sure the voltage is the same as the voltage listed on the unit.
Example: A 277/480 unit attached to a 480 Delta panel will blow the unit.

Do not open the unit unless you have to. If it becomes necessary to open the unit, excercise caution so that you do not loosen any wires.

lf you have any questions about exactly where to install the unit or installation procedures, please call our 800 number on the label on the unit

To discuss the size and type of Surge Supressor you need, call 800-221-3104.


[Secure Order]  [Secure Checkout]

Downloadable FAQ
(Read Product description - Not all products are downloadable)




Announcement List
Subscribe now and get a discount coupon for all purchase.

Name: *
Email: *


Back to the !Front Door! or DIRECTORY

Don't forget, you can not go wrong ordering from 4expertise.com Store...all our items are sent with a 30 day money back guarantee. We want you to be satisfied and shop here often. Call toll-free 800-221-3104 or email us if you have questions or comments.

Over 10,000 Brand Name Tools!


Free Shipping


Search the Web

Privacy Policy

Web Site Designed with Care by:
Carl G. Kline, MBA
copyright 1997-2005